Multiple PLC Trainer





Description:

Learning Objectives/Experiments

  1. PLC Programming Facility through P.C. 
  2. PLC Trainer contain 09 different reputed PLC where any two PLC does no use same brand, have used extra input/output module for interfacing different brand PLC.
  3. That’s why students can be programming, interfacing with input and output load from different reputed brands PLC.
  4. As a result, they are capable to control of machinery from industries where use of PLC.
  5. Programming Software with Math, Relay, Timer, Counter, Sequencer
  6. The constriction of nine different categories PLC.
  7. Interfacing method of nine different categories PLC.
  8. Programming method of nine different categories PLC.
  9. Pick & Place using PLC & Pneumatic Air Suction method.
  10. Pick & Place using PLC & Pneumatic Gripper method.
  11. Water Pump Control using nine different categories PLC.
  12. Fire Indication System using nine different categories PLC.
  13. Traffic Light Control using nine different categories PLC.
  14. The constriction of Pneumatic cylinder.
  15. Sequential control of three Pneumatic cylinder using nine different categories PLC.
  16. The constriction of Pneumatic solenoid valve.
  17. Control of Pneumatic solenoid valve using PLC.
  18. Interfacing of PLC & Pneumatic solenoid valve.
  19. The method of Control Relay using PLC.
  20. The methods of three phase Induction Motor Starter using PLC.
  21. Forward-and-reverse operation methods of three phase Induction Motor.
  22. The method of interfacing PLC with Input Switch.
  23. The method of interfacing PLC with Input Sensor.
  24. Operating method of interfacing proximity sensor with PLC.
  25. Operating method of interfacing photo sensor with PLC.
  26. Use of Variable Frequency Drive with PLC.
  27. Programming method of Variable Frequency Drive with PLC.
  28. The construction of Three Phase Induction motor.
  29. Interfacing Method of Three Phase Induction motor with VFD & PLC.
  30. The construction of Stepper Motor.
  31. Interfacing Method of Stepper Motor with PLC.
  32. The construction Seven Segment Display.
  33. Interfacing Method of Seven Segment Display with PLC.
  34. Interfacing Power Supply with nine different categories PLC.

 

Features

  • Main Voltage: 1 Phase 220V / 50/60Hz
  • Working Table: 1EA
  • Working Frame – 3 Step
  • Module Storage Cabinet: 2EA
  • Electric accessories Storage Cabinet: 1EA
  • Air Compressor: 1EA
  • Air compressor (basic equipment minimal machine): power: AC 220V±10% 50Hz/60Hz, motor power: 600W
  • Nominal volume Air compressor: 9L normal output voltage 0.7 MPa, noise degree: 66 dB
  • Connection facility 2mm & 4mm Safety Socket

 

NOTE: NINE PLC OF DIFFERENT MAKES TO CONDUCT ABOVE EXPERIEMENTS

  • PLC Category-01
  • PLC MAKE: SIEMENS -OR- EQUIVALENT
  • Programming Language: Ladder, Functional Flow Chart Diagram
  • Built in Ethernet communication
  • PLC Power supply: (1 No.)
  • PLC Digital Input: 08
  • PLC Analog Input: 04 Nos
  • PLC Analog Output: 02 Nos
  • PLC Digital output: 04
  • PLC Display Unit: YES
  • PLC Input Voltage: 24VDC, 1Amp
  • Permissible range, Lower limit (DC): 20.4V
  • Permissible range, Upper limit (DC): 28.8V
  • Programming Software: LOGO Soft Comfort or equivalent
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-02
  • PLC MAKE: MITSUBISHI -OR-EQUIVALENT
  • Power Supply: 24VDC
  • Input Types:24VDC
  • Output Types: Relay
  • Communication Options: RS-232 • RS-485, RS-422, USB
  • CPU Functions: High speed counters, 32-bit floating-point math
  • Program Memory Byte (Step): 128 K max. (64,000) Or higher
  • Ambient Temperature: 0-55° C (in operation) -20 ±70° C (in storage)
  • Ambient Humidity: 5-95% RH, no condensation (in operation)
  • Noise Immunity: 1000 Vpp noise voltage, 1 s pulse width at 30-100Hz
  • Digital Input: 8
  • Digital Output :8 (Relay)
  • Programming Software: Gx-Developer or equivalent
  • Programming Cable: SC-09 or equivalent
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-03
  • PLC MAKE: FATEK -OR- EQUIVALENT
  • PLC input: 8 points Digital
  • Triggering Power:24VDC
  • (2 points high speed 100KHz,
  • 2 points medium speed 20KHz,
  • 4 points medium speed total 5KHz);
  • PLC Output: 6 points relays
  • Communication Port:RS232/USB
  • Built-in power supply: SPW14-AC/D12/D24
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-04
  • PLC MAKE: OMRON -OR- EQUIVALENT
  • Power Supply=220 V AC
  • Digital Input =18
  • Digital Output=12(Relay)
  • Triggering Voltage:24VDC
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-05
  • PLC MAKE: DELTA -OR- EQUIVALENT
  • Power Supply=220 V AC
  • Digital Input =06
  • Digital Output=04(Relay)
  • Triggering Voltage:24VDC
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-06
  • PLC MAKE: ALLEN BRADLEY -OR- EQUIVALENT
  • PLC Digital Input:12 Nos
  • PLC Digital Output:07 Nos
  • PLC Analog Input:04 Nos
  • PLC Analog Output:01No
  • 20-point controllers
  • Provides embedded 0…10V non-isolated 4 channel analog input and 1 channel analog output for speed control of an AC drive
  • Provides embedded communications via non-isolated serial port (for RS-232 and RS-485 communications) and Ethernet port
  • Communicates via Ethernet/IP™
  • Provides embedded microSDTM slot for program transfer, data log, and recipe management
  • Provides embedded support for up to four 10k thermistor temperature inputs
  • Supports program download through USB with an optional 3.5-in. Remote LCD
  • Supports up to two Micro800®Plug-in Modules
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-07
  • PLC MAKE: LS -OR- EQUIVALENT
  • Power Supply=220 V AC
  • Digital Input =18
  • Digital Output=12(Relay)
  • Triggering Voltage:24VDC
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-08
  • PLC MAKE: SCHNEIDER ELECTRIC -OR- EQUIVALENT
  • Built in display: LCD
  • High-speed Operation
  • Number or control scheme lines
  • Maximum Number of I/O Points:
  • 0…500 with FBD programming
  • 0…240 with ladder programming.
  • Cycle time: 6…90 ms
  • Backup time: 10 years at 25 °C
  • Checks: Program memory on each power up
  • Supply voltage limits: 19.2…30 V
  • Discrete input voltage: 24 V DC
  • Discrete input current: 4 mA
  • IP degree of protection: IP20 (terminal block) conforming to IEC 60529
  • Mechanical durability: 10000000 cycles (relay output)
  • Output thermal current: 8 A for all 4 outputs (relay output)
  • Discrete input number: 6 conforming to EN/IEC 61131-2 type 1
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

  • PLC Category-09
  • PLC MAKE: WECON -OR- EQUIVALENT
  • Power Supply=220 V AC
  • Digital Input =08
  • Digital Output=06(Relay)
  • Triggering Voltage:24VDC
  • Programming Cable: PLC to PC communication Cable
  • Connection facility 2mm & 4mm Safety Socket
  • Module Dimension: L x W x H (mm):295 x 225 x 44

 

Send us Enquiry








Visit Us

Office: S. N. 37/02, "Ashtavinayak Indl. Estate", Parvati Nagar, Dhayari Narhe Road, Next to Pari Robotics, Narhe, Pune-411041
Tel fax: (020) 24690312,
Email: sales@xeepl.com, xeepl.pune@gmail.com

Lets Visit

Become a Facebook Fan