HUMIDITY / STABILITY TEST CHAMBER:





Description:

 

HUMIDITY / STABILITY TEST CHAMBER:

  • Precise Hot Air & Humidity.
  • Better Mineral / Glasswool / Puf Insulation Keep the surface Temperature comfortable & Avoid Heat & Humidity Loss.
  • Silent Hot Air Blower, Unique design of Air Circulation & Humidity circulation & improved Temperature / Humidity distribution.
  • Unique design of Ventilation.
  • Polish 304 grade of S. Steel interior Corrosion resistant long life operation
  • Kanthal A-1 Tubular heater is fitted for better circulation.
  • Safety controller is provided with Digital Temp. Controller cum Indicator.
  • Kanthal A-1 steel Tubular heater J shape is fitted in the steam Bath for long life & better result.
  • Full feature with Temp. Controller i.e. Thermostat Bi-Metallic Capillary type for both Dry & Wet Temp. Control or Digital Temp. Controller Cum Indicator & Microprocessor Based PID Temp. Controller Cum Indicator.
  • Choose among the models with window front glass door or inner Perspex / Acrylic sheet Door with full view to observe the Test process inside the chamber while keep Temperature uninterrupted.
  • Angle Iron frame with castor wheel for easy movement (for Refrigerated model )
  • Fitted with 02 Nos. Fan for cooling & heating (For Refrigerated Model)
  • Filled with 02 Nos. Circulation motor for water injection in routine model inside the control unit & Chamber.
  • Humidistat is placed inside the chamber to control requested humidity.
  • Humidity can be controlled by Digital Temp. & Humidity (Both automatically on customer requirement).
  • Wet Temp. is controlled by Bi-Metallic Thermostat Connected to Water Bath placed in the control unit having water level. (Nozzle for Water inlet & outlet & overflow).

 

Technical Parameters :

Temperature Range :

:

Ambient to 45 °C

Temperature Stability :

:

±1°C

Housing Material :

:

CRC / Mild Steel Sheet duly Powder Coated

Power Consumption :

:

220/230V, AC ± 10% 50Hz Single Phase

Safety Function :

:

Water Level & Low water level cut off alarm (On customer request)

Optional :

:

RS 232 Communication Interface

Duty Cycle :

:

Continuous

Interior :

:

S.S. 304 Polished Sheet

Humidity Range:

:

Ambient to 95% ±3% (For Routine Model)

Temp. Range :

:

10 - 50°C (For Cooling Refrigerated Model)

Humidity Range :

:

55 - 92% ±3% (For Cooling Refrigerated Model)

Compressor :

:

Kirloskar/ Tecumseh As per model requirement (For Cooling below Ambient)

Voltage Stabilizer :

:

Required for Cooling (Refrigerated Model as per size/ model)

Refrigerant :

:

R 134/22 (For Cooling Model)

Optional :

:

Digital Timer

Wet & Dry Thermometer for Calibration

Precaution :

:

Don't use the Instrument without water

 

Available in following Sizes: 

Chamber Size (Inside)

S. Steel / Aluminium

No. of Trays

Ltr

Wattage

18”X18”X18” (450X450X450mm)

2

95

1 KW

18”X18”X28” (450x450x700mm)

2

147

1 KW

24”x24”x24” (605x605x605mm)

2

225

1.5 KW

24”x24”x36” (605x605x900mm)

3

335

1 KW

 

Send us Enquiry








Visit Us

Office: S. N. 37/02, "Ashtavinayak Indl. Estate", Parvati Nagar, Dhayari Narhe Road, Next to Pari Robotics, Narhe, Pune-411041
Tel fax: (020) 24690312,
Email: sales@xeepl.com, xeepl.pune@gmail.com

Lets Visit